Minimum Order Quantity | 10 Piece |
Model Name/Number | Spectrum SERIES 160 STAINLESS STEEL PITOT TUBE |
Usage/Application | HVAC |
Size | as per requirement |
Material | SS |
Pressure Connection | 1/4" 1/8" |
Packaging Type | Standard |
Shape | L shape |
Process Connection | 1/4" |
Power | Not required |
Product Type | Pitote tube L shape |
Electricity Supply | Not required |
Brand | Spectrum |
Model Name/Number | 160S-18 |
Usage/Application | HVAC |
Pressure Connection | 1/8 NPT |
Weight | Less then 1 KG |
Power | Not required |
he Series 160S “S” Type Stainless Steel Pitot Tube is designed specifically for flow measurement of dirty, particulate laden air or gas streams typical in smoke stack and other environmental testing. Total and static pressure tubes are precisely aligned and welded together every 6 inches for maximum accuracy, strength, and long term durability. Permanent mount (PM) models include a 1" welded stainless steel sleeve and adjustable compression fitting with 1" MNPT mounting threads.
Note: Special shipping and handling charges will apply to pitot tube lengths over 36" for International orders and 72" for Domestic orders.
PRODUCT APPLICATIONSMinimum Order Quantity | 5 Piece |
Hook Type | Duct mounted |
Brand | E+E Elektronik |
Accuracy | Accuracy at 20 DegreeC 2) (68 DegreeF), 0.2...10 m/s (40...2000 ft/min) +- (0.2 m/s (40 ft/min) + 3 % of m. v.) |
Range | Accuracy at 20 DegreeC 2) (68 DegreeF), 0.2...10 m/s (40...2000 ft/min) +- (0.2 m/s (40 ft/min) + 3 % of m. v.) |
Color | White and Green |
Model Name/Number | EE650-T2-A6-L200 |
Service | Air Velocity Transmitter for HVAC Applications |
Mounting Type | Duct |
Power | Power supply (Class III) 24 V AC/DC +- 20 % |
Series | EE650 |
Usage/Application | HVAC, Clean Room, Air velocity measurement |
Detector Type | Fixed Single Gas |
Name of Gases Detected | Carbon monoxice |
Brand | Dwyer |
Model | CMT200 |
Power Source | Power supply |
Display Type | Analog |
Measuring Range | 0-200PPM |
Weight | 0.28 lb (0.11 kg) |
Housing | UV resistant polycarbonate |
Temperature Limits | -4 to 122 DegreeF (-20 to 50 DegreeC). |
Minimum Order Quantity | 1 Piece |
Suitable Media | Gas |
Brand | Janatics |
Part Number | PS0108504A |
Pressure Range | 1-10Bar |
Output | 1 PNP Output |
Supply Voltage | 12V to 24V DC |
Country of Origin | Made in India |
Minimum Order Quantity | 1 Piece |
Type | Air Flow Sensor |
Brand | E+E |
Accuracy | +-1.5 % of the measured value |
Output | 0-10 V, 0/4-20 mA, Pulse, Switch, Modbus RTU or M-Bus |
Material | 18 - 30 V AC/DC |
The flow sensor can measure the consumption of compressed air, nitrogen, oxygen, COâ‚‚, argon or other non-corrosive gases. The measurement ball valve permits easy installation and removal with only a short interruption of the flow.
EE771 flow sensor employs the well proven E+E hot-film sensor element with high immunity to contamination, which leads to outstanding long-term stability and accuracy even under harsh operating conditions.
With wide measuring range from 0.5 to 200 Nm/s (100...39370 SFPM) (1:400) and fast response time, one and the same flow meter model can be employed throughout the entire gas supply system. It records accurately even the smallest flow which represent an essential prerequisite for calculating consumption costs or for finding leaks.
Every E+E flow sensor undergoes a precise factory calibration procedure at a pressure of 7 bar (102 psi), the corresponding calibration certificate is included in the standard scope of supply.
The EE771 flow sensor is available with an additional MODBUS RTU or M-BUS (Meter-Bus) interface.
Spectrum Enterprises is a largest supplier of E+E product in India major cities like Mumbai, Bangalore, Chennai, Kolkata, Delhi, Ahmedabad, Vadodara, Pune, Aurangabad, Kochi, Visakhapattanam, Hyderabad.
Material | ABS |
Hook Type | Clamp |
Brand | E+E Dwyer Testo |
Display Type | Optional |
Accuracy | 2% |
Range | 0-20 ,meter per second |
Color | White Green Red |
Model Name/Number | EE650 |
Service | Air Gas |
Humidity | 0-100% |
Mounting Type | Duct type |
Power | 0-12V |
Size | Compact |
Temperature | 0-60 Deg C |
Process Temperature | 0-60 Deg C |
Ambient Temperature | 0-60 Deg C |
Several Measuring Ranges | 0-2 meters per second, 0-20 meters per second, 0-40 meters per second |
Usage/Application | HVAC, Clean room, Operation Theater, Laminar Air Flow, Fluid Bed Drier |
Features:
Compact size
Easy to use
Efficient functionality
Functions:
Air flow sensor for laminar flow monitoring
Measuring range: 0...1 m/s; 0...1.5 m/s; 0...2 m/s (adjustable by jumpers)
Brand | E+E Elektronik |
Model Name/Number | EE576 |
Input Phase | Single Phase |
Input Voltage | Supply voltage (Class III) 10 - 19 V DC or 19 - 29 V DC |
Mounting Type | Flange |
Part No. | EE576 |
Diameter | As per datasheet |
Display | Not applicable |
Temperature | Temperature working range -20...60 DegreeC (-4...140 DegreeF) storage range -30...60 DegreeC (-22...140 DegreeF) |
Accuracy | Accuracy1) 0.2...1 m/s (40...200 ft/min): +-(0.05 m/s +2 % of mv) at 20 DegreeC / 68 DegreeF / 45 % RH and 1013 |
Equipped with a newly developed sensor head and utilizing the proven E+E hot-film element, already tested a million times in the automotive industry, these transmitters are less sensitive to dust and dirt than conventional hot-wire elements.
This is reflected in the excellent reproducibility and proven long-term stability of the measuring results. The factory calibration with a special wind tunnel for lowest velocity ensures optimal precision and maximum sensitivity. The EE576 can be mounted fast and easily.
The alignment strip along the probe’s tube and the matching mounting flange determine the orientation of the sensor probe. The mounting flange allows for an infinitely variation of the depth of the sensor probe. The electronics integrated in the probe tube provide a linear analogue signal of 0-5V or 0-10V for the velocity range 0...2m/s (0...400ft/min) or 0...1m/s (0...200ft/min).
Type | Air Flow Sensor |
Application | HVAC |
Accuracy | 3% |
Output | 0-10 VDC |
Supply Voltage | 24 V DC |
Material | Plastic |
The EE650 air flow sensor is dedicated for accurate and reliable measurement in building automation and ventilation applications. EE650 employs the new VTQ air flow sensor element, which operates on the thermal anemometer principle and is manufactured by E+E in state-of-the-art thin film technology.
Due to its innovative design, the VTQ air flow sensor element is very robust and highly insensitive to pollution, which leads to outstanding long-term performance.
The measured data is available either on an analogue voltage or current output, user selectable, or on the RS485 interface with Modbus RTU or BACnet MS/TP protocol.
The enclosure design and the mounting flange included in the scope of supply allow for easy installation or replacement. The configuration and adjustment of the EE650 can be comfortably performed on the electronics board or via digital interface.
Typical Applications
Usage/Application | Industrial |
Material | Plastic |
Accuracy | 0.05 % |
Measuring Temperature | 5m/s |
Response time | 4 Second |
Supply | 19V DC |
The EE575 is a compact Miniature air flow sensor designed for high volume applications. Due to the small design, the module can be fitted to nearly every application. The use of a high-quality E+E thin film sensor element based on the hot film anemometer principle ensures optimal precision and maximum sensitivity. The innovative design makes E+E velocity sensor elements less sensitive to dust and other pollution than conventional hot wire anemometers. This is reflected in the excellent reproducibility and proven long-term stability of the measuring results.
Features:
Usage/Application | 1000 |
Accuracy | 0.06 % |
Measuring Temperature | 2m/s |
Operating range | 40m/s |
Velocity | 20m/s |
Outputs Current | 10 V |
Supply | 24V AC/DC |
pressure-tight models | 10bar |
Response time | 40s |
The EE75 series High Accuracy Air Flow Sensor were developed to obtain accurate measuring results over a wide range of velocities and temperatures. A high-quality hot film sensor element based on cutting- edge thin film technology ensures maximum sensitivity, even at lowest mass flows.
Minimum Order Quantity | 1 Piece |
Usage/Application | Flow measurement |
Brand | Honeywell Sensing |
Model Name/Number | AWM5104VN |
Media | Air Or Gas |
Material | As per catalogue |
Weight | 60 grams (2.12 oz.) |
Flow Range | 0-20 SLPM |
Packaging Type | Standard |
Type | L shape |
Material | Stainless Steel |
Surface Finish | Anodized |
Shape | Round |
Brand | Dwyer Instruments USA |
Outer Diameter | 5/8" |
Temperature | As per datasheet |
Place Of Origin | USA |
Is It Corrosion Resistant | Corrosion Resistant |
Color | SS standard |
Usage/Application | HVAC |
The Series 160 Stainless Steel Pitot Tube is constructed from corrosion resistant stainless steel with permanently etched insertion depth graduations for a lifetime of service. The static pressure port is parallel to the sensing tube to allow quick, easy alignment of the tube with air flow. A universal model fits the user supplied 3/4" schedule 40 pipe in any length.
Note: Special shipping and handling charges will apply to pitot tube lengths over 36" for International orders and 72" for Domestic orders.
Download the Air Velocity Calculator App for Android® devices.
PRODUCT APPLICATIONSModel | Description |
---|---|
160-12 | Stainless steel Pitot tube, 5/16" dia., 12-5/8" insertion length. |
160-18 | Stainless steel Pitot tube, 5/16" dia., 18-5/8" insertion length. |
160-24 | Stainless steel Pitot tube, 5/16" dia., 24-5/8" insertion length. |
160-36 | Stainless steel Pitot tube, 5/16" dia., 36-5/8" insertion length. |
160-48 | Stainless steel Pitot tube, 5/16" dia., 48-5/8" insertion length. |
160-60 | Stainless steel Pitot tube, 5/16" dia., 60-5/8" insertion length. |
160-8 | Stainless steel Pitot tube, 5/16" dia., 8-5/8" insertion length. |
160-KIT | Kit containing 160-18, 160-24, 160-36, 160-48, and FREE carrying case ($150 value) |